Gage R&R (gauge R&R) · MSA type 2 Gage R&R calculator: %GRR and ndc from your study
Enter your measurements – %GRR, ndc and the variance components update as you type. Calculated with analysis of variance (ANOVA). No sign-up, and the measurements never leave your browser.
Last updated: November 6, 2026 · Reviewed by irot
- Free for up to 20 devices
- No payment details
- Interface in English and German

The calculator
The usual study design is ten parts, three appraisers, two trials. Fewer works too – the calculator then tells you that the result is less reliable. You can paste values from Excel into the grid: a row or a block, starting at the cell you are in.
Tolerance or total variation – the number depends on it
There are two %GRR figures, and both are correct. One relates the variation of the measurement system to the tolerance of the characteristic, the other to the total variation of the parts you measured. That is not a detail: take ten parts from the same batch and you get a devastating result against total variation and a good one against the tolerance.
The calculator uses the tolerance as soon as you enter one – it is the question your customer asks. Without a tolerance only total variation is left, and the result says which reference it uses. If the two figures are far apart, the calculator tells you: then the parts you chose do not cover the tolerance range, and that is a flaw in the study, not in the gauge.
What the numbers mean
- EV – repeatability
- Same appraiser, same part, measured twice. Whatever varies here varies in the instrument and the fixture.
- AV – reproducibility
- The difference between appraisers. If it is large, the cause is rarely the people and almost always an instruction that leaves room for interpretation.
- GRR – both together
- The share of the variation that comes from the measurement system. Common guideline values: up to 10 % acceptable, 10 to 30 % may be acceptable, above 30 % not acceptable. Your customer may require other limits.
- ndc – number of distinct categories
- How many groups the measurement system can still tell apart within the part variation. At least 5 is the usual requirement. Below that you can sort, but not measure – and a control chart becomes meaningless.
- Part × appraiser interaction
- Some appraisers measure certain parts differently from others. The calculator tests this with an F-test and then uses the matching model. If the interaction is not significant it is pooled into repeatability; your customer's statistics software may handle this differently, so agree the method with your customer.
How to set up the study
- Choose parts that cover the tolerance range. Ten parts from one batch is the most common mistake: the result then measures how alike the parts are, not how good the measurement system is.
- Mark every part – but so that the appraiser cannot see the number while measuring.
- Randomise the order and let the appraisers measure separately. Measuring the parts twice in the same order also measures the appraiser's memory.
- Use normal conditions: the same fixture, environment and instruction as in production.
- Do not correct afterwards. An outlier that is removed is information that is lost – usually the most important.
How it is calculated
With analysis of variance (ANOVA), not the older range method. That matters to you: ANOVA needs no table constants and separates the part × appraiser interaction cleanly. Every intermediate step can be recalculated – you do not have to trust us, and you do not need to buy a manual to check.
The reference to the tolerance uses six standard deviations (99.73 %). Older editions of the manuals used 5.15 (99 %). If you compare a figure from an old report, you are comparing two definitions, not two measurement systems.
The Kalibrat application uses the same calculation; an automated test runs both versions over the same data and compares them.
Type 1, type 2 or type 3?
The study on this page is the one with appraiser influence (often called MSA type 2 or simply gage R&R – also spelled gauge R&R). Next to it are the type 1 study – one appraiser measures a reference with a known value many times, giving Cg and Cgk for the instrument alone (Cg and Cgk calculator) – and the type 3 study, like type 2 but without appraiser influence because a machine measures. Kalibrat's IATF 16949 module covers all three and keeps each study with the gauge it belongs to.
Does this apply to us?
Yes, if your customer requires, under IATF 16949, statistical studies of the measurement systems listed in the control plan. In the automotive supply chain that is the rule. Not necessarily if you are certified to ISO 9001 only: it requires traceable, suitable measuring equipment, but no measurement system analysis as such.
Sources: IATF 16949 clause 7.1.5.1.1; method and limits follow the AIAG MSA reference manual and VDA volume 5. Both manuals are sold by their publishers and were not checked word for word here; the figures above are the widely used recommendations.
Frequently asked questions
What is a good %GRR?
Common guideline values: up to 10 % the measurement system is acceptable, 10 to 30 % it may be acceptable depending on the application, cost and customer, above 30 % it is not acceptable. Your customer's requirement is binding.
What does ndc mean?
The number of distinct categories: how many groups the measurement system can reliably tell apart within the part variation. At least 5 is the usual requirement.
ANOVA or range method?
This calculator uses ANOVA. It needs no table constants and separates the part × appraiser interaction. Results can differ slightly from range-method results.
Is my data uploaded?
No. The calculation runs entirely in your browser; nothing is sent to a server.
Keep your MSA studies with the gauges they belong to
Free for up to 20 devices, for as long as you like, with no payment details. Set up in three minutes – e-mail, your company, done. Your spreadsheet comes along.